草成人在线观看,玖玖玖亚洲精品,2008高清一道国产,av免费在线观看网站不卡顿

Language
News
News

With years of experience in designing and assembling complete sets of generator sets

What is the function of a diesel generator circuit breaker? What if the circuit breaker cannot be closed?

Time:2023-12-12

The circuit breaker of a diesel generator set is a switching device that can close, carry, and disconnect current under normal circuit conditions, close the circuit breaker within a specified time, and conduct and disconnect current under abnormal circuit conditions. Circuit breakers can be used for power distribution, infrequently starting diesel motors, protecting power lines and motors. When serious overload, short circuit, undervoltage and other faults occur, the circuit can be automatically cut off. Its function is equivalent to a combination of a fuse switch and an over/under heating relay. And usually there is no need to change the components after disconnecting the fault current. In addition, the circuit breaker of the diesel generator set also needs to have the following functions:

1. The circuit breaker should be able to operate reliably for a long time under rated conditions.

2. It should have sufficient short-circuit capacity. Due to the reliable voltage and high current of the power grid, when the circuit breaker opens, a strong arc is generated between the contacts. Only when the arc is completely extinguished can the circuit be opened. Therefore, it is required that the circuit breaker has sufficient short-circuit capacity, especially in the event of a short-circuit fault, it should be able to reliably cut off the short-circuit current and ensure sufficient thermal and dynamic stability.

3. Have the shortest possible start time. When a short circuit fault occurs in the power grid, it is required that the circuit breaker quickly cuts off the faulty circuit, which can shorten the fault time of the power grid and reduce the harm of short circuit current to short-term equipment.

How can we solve the problem of the circuit breaker not closing when we use diesel generators?

Firstly, you can use a Phillips screwdriver to unscrew the two screws that secure the circuit breaker. Then use a cross screwdriver to remove the red wire behind the circuit breaker, take out the circuit breaker, gently tap it on the table to ensure it is not damaged, and then try to close the circuit breaker! If it can be closed, it's fine. If it can't be closed, keep slapping! After the circuit breaker is tapped normally, install it correctly to ensure stable installation. Then fasten the generator circuit protection board and tighten all the screws on the front panel!

Guangzhou Saiwei Energy Technology Co., Ltd. is a comprehensive enterprise specializing in design, production, and generator installation. Guangzhou Saiwei has many years of experience in engineering design and installation services. For many years, Guangzhou Saiwei has been committed to providing every customer with comprehensive products and energy solutions, including technical consulting, whole machine and generator supply, operation training, etc., with leading technology and first-class quality. The product range covers land diesel generator sets, marine generator sets, high-voltage generator sets, etc., and is widely used in industries such as power, communication, iron towers, healthcare, financial systems, data centers, etc. Welcome to inquire: 13302262088


柘荣县| 闽侯县| 青岛市| 江川县| 平罗县| 侯马市| 祁连县| 奎屯市| 肃宁县| 黎川县| 改则县| 拜泉县| 榕江县| 开鲁县| 新建县| 万州区| 镇江市| 健康| 铜鼓县| 米脂县| 锡林浩特市| 正定县| 濉溪县| 荔浦县| 尼玛县| 丹寨县| 霍山县| 太原市| 滁州市| 民丰县| 维西| 邛崃市| 洪泽县| 巴彦淖尔市| 玉林市| 五原县| 大兴区| 山丹县| 固安县| 崇仁县| 孝昌县|